An Eos whose roof stops halfway and beeps at the driver has almost always lost one signal from the chain of microswitches that reports where each part is. The roof module will not continue a sequence it cannot verify, so it stops and waits. The order below finds the switch that never reports before the module is blamed.
The owner holds the switch and the roof moves part of the way, then everything stops with a warning on the dash and a beep. Some report that the roof will close but not open, or that it stops at the same point every time. Ask which point in the sequence it stops at, because that point names the switch that should have reported next.
Ask whether the fault came on after work in the boot or after the parcel shelf was loaded. A blind that is not in its seat stops the sequence at the first step, and a bag left on the shelf gives the same complaint. Write those answers on the sheet, since they decide whether you open the tester at all. Ask about a slope as well, because a roof opened on an incline pulls air into the pump.
Read the roof module and open the page that lists every switch in the chain. Each entry shows open or closed, and the whole diagnosis rests on that page. Operate the roof slowly and watch the list, then write the status of every switch at the moment the roof stops.
A switch that never changes while its part of the roof moves is the one to test. A switch that changes and then falls back has a loose plug or a broken wire at the hinge. Keep the list on screen while the roof moves, because a status that flickers for a moment is easy to miss and it stops the sequence just the same. Read the page once with the engine off before the cycle begins.
The roof will not start unless the boot blind is in place and its switch is closed, so that switch is checked first. Read its status, then press the blind into its seat by hand and read again. A blind that is slightly out of its guide closes the switch intermittently and stops the roof at random.
Check the boot lid switch and the two frame locks as well, since the module waits for all of them. Measure the supply and the ground at the module plug with the ignition on, then load the feed with a bulb. A module that loses its feed while the pump runs stops the sequence at whatever point it reached. Read the feed again with the pump running, since a supply that sags under that load sends the module into a reset.
Unplug the chain at the module and measure resistance through it from end to end with the roof in a known position, then compare the figure with the same chain on a car that works. A chain that reads open has a switch or a wire in it that is not passing current, and the tester page names the segment. Take that reading with the roof in the position where it stops, since a chain that is open in one position reads closed in another.
Test each switch on its own with the meter across its terminals while the part is moved by hand. A switch that reads open when it should be closed has failed, and one that reads closed in both positions holds the module in a step it has already finished. Write each result against the switch name on the sheet.
The hydraulic pump is commanded by the module, and its current is read with a clamp while the roof moves. A pump that pulls a heavy current and moves nothing has a seized pump or a blocked line. One that pulls almost nothing has an open winding or a relay that never closes.
Read the fluid level at the pump with the roof in the closed position and the car on level ground. A level that is low draws air into the lines and the roof moves in jerks before it stops. Look at the fluid colour, because a dark fluid with particles points at a pump that is wearing and a repair that will return. Note the fluid temperature too, since a cold system moves slowly and fools the current reading.
The roof moves, so the loom that serves it flexes at every cycle, and the wires break inside the insulation where the hinge bends. Flex each branch by hand while the switch page is on screen and watch for a status that drops. That test finds the wire that a continuity check passes when the roof is still.
Open the plugs at the roof shells and look for a green pin or a shell that has been forced. Water reaches these plugs through the roof drains, and a drain that is blocked sends water along the loom to the module. Check the drains at the same time, since a repair that leaves them blocked returns within a month. Photograph the plug before you touch it, because the pin order on these shells is easy to lose.
On the bench the module is powered at thirteen and a half volts and each switch input is bridged in the order the roof would close it. A module that runs the pump output at the right step is healthy. One that refuses to advance with every input correct has a fault on its input side. Bridge the inputs one at a time and write each step down.
Load the pump output with a lamp or a test motor and watch the current the module can carry. An output that holds under that load is good, and one that collapses has a driver that is failing. Keep the unit powered for several minutes, since these modules sit in a damp place and they fail when warm.
Fit the module and the parts, connect the battery, then run the roof through a full open and close cycle with the engine off. Watch every step and let each one finish before you touch the switch again. A sequence that completes once and fails on the second cycle has a wire that is still marginal, and it is found with the loom test.
Write the switch statuses on the sheet with the chain resistance and the pump current, then add the fluid level. That record is what makes the second visit short, and it also shows whether a switch has moved since. Ask the owner to keep the blind in place and the drains clear, since both bring this complaint back.
Run the roof through three complete cycles with the engine running and the battery charged, because a module that sees a low supply stops the sequence to protect the pump. Read the battery voltage at the moment the roof stops and write it beside the switch statuses. Take that reading during the cycle as well as before it, because a supply that holds at rest can fall away under the pump. A car that stops at the same step with a good supply has a switch that is failing under movement.
| Symptom | Likely cause | What is measured |
|---|---|---|
| Roof stops at the first step | Boot blind not seated | Blind switch status, then the supply at the module |
| Roof stops at the same point | One switch not reporting | Switch statuses on the tester at the moment it stops |
| Roof moves in jerks, then stops | Low fluid or air in the lines | Fluid level at the pump, current while it runs |
| Works once, fails on the next cycle | Broken wire at the hinge | Status page while each branch is flexed by hand |
The roof has a manual procedure in the book, and it is used to get the car home. The switch statuses are read before that, so the step it stopped at is not lost.
The module waits for a switch that never reports at that step. The tester page shows which one, and a continuity test at that switch confirms it.
Rarely. A switch that never reports, or a wire broken at the hinge, explains most of these complaints, and both are measured before the module comes out.
The roof is run through a full cycle with the engine off, then three more with it running. The switch statuses and the pump current are compared with the figures from before.