The truck was boosted from another vehicle and it has not started since. The dash lights up and the engine turns, and the tester cannot reach the unit at all. A boost that went in the wrong way, or a spike from a running donor, is the usual story behind a silent unit on these trucks.
The history is the most useful thing you have here, because a fault that arrived during a jump start points at the supply and the protection around the unit rather than at something that wore out over years. Ask who connected the leads and in what order, and whether the donor engine was running. A reversed connection sends current through the ground path and takes out whatever protects the unit. A running donor can spike the feed and do the same damage quietly.
Ask whether the truck ran for a while after the boost and then stopped, because that pattern means the charging side took the unit out rather than the leads. A unit that died minutes later was killed by a spike on the charge circuit. A unit that never fired again was killed when the leads touched. The difference changes what you test first.
A reversed connection puts current through the unit ground and through protection devices that were never meant to carry it. Those devices sit behind the feed pins and they fail short, which leaves the unit with no supply at all. Look at the board near the connector before you power anything up, because the damage is usually visible as a burnt track. A blown protection device is a repair rather than a replacement.
A spike from a running donor does its damage inside the driver stages instead, and the unit may still answer on the tester while it refuses to fire the coils. That is the fault that looks like an ignition problem until you read the codes. Ask which of the two stories fits the truck in front of you before you open the case.
Check every fuse in the engine bay box with a meter rather than by eye, and check the main fuse links as well. A link that has opened under a reverse connection is the whole repair on some trucks, and it costs a few minutes to test. Pull each fuse and read it on the meter, then look at the socket for heat marks. A socket that has been hot loses its tension and gives a fault that comes and goes.
Measure the feed at the unit plug with the ignition on and load it with a bulb. A feed that collapses under a lamp has a joint behind it, and the unit will drop out the moment it asks for current. Trace that joint back through the fuse box and along the main cable. A clamp that has been overtightened and has cracked is worth a look.
Measure the unit ground pins to the battery negative post on the millivolt scale with the ignition on. A return above a few tens of millivolts is poor enough to upset a unit that switches coils, and a reversed connection often damages the ground path before anything else. Clean the earth points on the inner wing and at the block, then read again. A drop that improves was the fault.
Backprobe the five volt reference at a sensor plug with the unit connected and read the voltage. A reference at zero with the unit plugged in points at a sensor pulling the line down, so unplug sensors one at a time and watch the value return. A reference that never returns has a dead supply inside the unit. That test separates a sensor fault from a unit fault in a few minutes.
Scan the whole truck and note which addresses answered, because a unit that is silent while its neighbours talk has lost a feed or has died inside. A unit that answers with a list of sensor codes has power and a live bus, and the fault sits on an output or a reference. The second case is the better news of the two. Write the address list down before you clear anything. A unit that answers and then drops off the scan has a supply that is marginal.
Compare the bus resistance at the diagnostic socket with the specification, since a unit that has failed short can pull the whole network down. A pair that reads far below the expected value has a module shorting it, and the unit is unplugged to see whether the reading recovers. That test protects the rest of the network from a bad unit. Note the reading on the sheet before the unit comes unplugged.
Watch the security lamp during the first seconds of cranking, because a boost can leave the key data disturbed and the truck will then crank without firing. A lamp that keeps flashing with the key in place means the unit has not accepted it. Try the second key and watch the lamp again. A key that has lost its data gives a crank with no start and no codes on some testers.
Read the security status in live values while the key is turned, and note whether the unit reports the key as valid. A valid key with no start sends you back to the fuel and spark side. An invalid key with a good supply puts the work on the key data and on the unit memory together. Both are restored on the bench.
On the bench the unit is fed at thirteen and a half volts and the outputs are loaded with lamps. A unit that talks and switches has survived the boost, and the fault is in the truck. A unit that stays silent has a dead supply section, and the repair is on the board behind the feed pins. Test the outputs the truck complained about before you sign it off.
Ask for the key data and the coding to be read before the case is opened, since a unit that has lost its memory needs both restored. Look at the board for a burnt protection device and a discoloured track near the connector. A device that has failed short is replaced and the feed is tested under load afterwards. Photograph the repair for the file.
Fit the unit, connect the battery and scan the truck before you crank. Read the security status and confirm the key is accepted, then start the engine and let it idle. Switch off and restart it warm, because a unit that has been repaired can fail again when it heats up. Check the charge voltage at the battery with the engine running. A figure below the specification points at the alternator and explains the first failure.
Ask what killed the first unit before the truck leaves, since a charge fault will kill the second one the same way. Test the alternator under load and look at the battery for a cracked case or a loose post. Write the feed and ground values on the job sheet with the bench result. Hand the truck back with the charge voltage noted for the owner.
| Symptom | Likely cause | What is measured |
|---|---|---|
| Cranks, no start, unit silent | Protection device failed short | Feed at the plug, loaded with a bulb |
| Unit answers, no spark | Driver stages damaged by a spike | Outputs under load on the bench |
| Reference at zero volts | Sensor pulling the line down | Reference with sensors unplugged in turn |
| Cranks with the security lamp on | Key data disturbed | Security status on both keys |
It can, and the damage usually sits right behind the feed pins where the protection devices are. That damage is visible with the case open and it is repairable on the board.
A crank with no start means the starter circuit is intact and the unit is not firing the engine, which can be lost key data or a dead output. The security lamp during cranking separates the two.
They are, because a main fuse link opens under a reverse connection and stops everything. A meter across each fuse takes a few minutes and rules the supply out before the case is opened.
The key data and the coding are read from the old unit where possible and written back on the bench. A unit that has lost its memory is restored rather than replaced when the board is sound.