A 320i that turns over and never catches is one of the most common arrivals on this engine, and the engine control unit is blamed early. The MSV80 decides when to fire, so a crank with no start can sit inside the unit itself. The order below separates a dead driver stage from a fuel or signal fault before anything is replaced.
The starter turns the engine at the sound it always makes and the engine never catches, even for a moment. That sound removes a flat battery and a dragging starter from the job before a single test is made, and it leaves the firing side as the subject. Ask the driver whether the engine stopped after a cold start, at speed, or after a short trip. Each answer points at a different part of the unit.
Ask as well whether the car stood for weeks with a low battery, because a unit that has sat on a falling supply can lose its coding. A jump start from a running vehicle belongs in the same question, and so does any welding repair on the body. Write the answers next to the mileage on the sheet, since the story decides which measurement comes first.
Measure the battery with a load tester and read it again while the starter turns, since a battery that holds twelve and a half volts at rest can fall under ten during the crank. The MSV80 resets below that level and stops scheduling a spark. Fit a charger or a known good battery before any conclusion is drawn, then repeat the crank.
Measure the permanent feed at the unit connector with the plug fitted and fine probes through the seal, and measure the ignition feed in the same way. Both should sit at battery level and the ignition feed must hold through the whole crank. Then measure the ground pins against the battery post on the millivolt range, where a drop above fifty millivolts disturbs both the unit and the coil earths.
Fit a spark tester to one coil and crank with the tester grounded on the head. A spark that jumps a good gap on two cylinders rules the ignition side out and moves the job to the fuel side. No spark at all on two coils sends you to the crank signal and to the unit trigger output, which is measured at the coil plug next.
Connect a noid light or a scope to an injector plug and crank again. The MSV80 on this engine fires the injectors through driver stages inside the housing, and a unit that gives no pulse on any cylinder while the coils still spark has told you where the fault sits. Compare one cylinder against the next before the unit is opened.
Each injector has its own stage and each stage has a sense circuit, so one failed stage leaves three cylinders working and the engine running rough. A unit that has lost the sense circuit on all stages cuts injection completely and leaves the coils working. Read the fault memory for injector output entries and write the cylinder numbers down.
Scope the control wire at the injector plug with the ignition on and the engine cranking, and look at the shape as well as the presence of the pulse. A pulse that is present but flattened, or one that appears for a second and then disappears, describes a stage that is shutting itself down on a current fault. That behaviour belongs to the unit and to the injector winding together.
The unit will not pulse the injectors until it sees pressure in the rail, so a car with no start and no injector pulse can be a fuel fault wearing the same clothes. Read the rail pressure live during the crank and compare it with the value the unit expects. A rail that stays at zero while the pump runs is a pressure fault.
Measure the low side feed with a gauge at the pump outlet, and measure the pump current with a clamp on the feed wire, since a pump that draws a high current is worn and a pump that draws almost nothing is open circuit. Watch the pressure while the starter turns for at least five seconds, because the first turn rarely builds the value the unit wants. Listen at the filler neck as the key is turned, because a pump that runs for a second and stops is doing what the unit asked.
Scope the crank sensor while the engine turns and confirm a clean pattern with a steady amplitude at cranking speed. A ragged or missing trace means the sensor or its air gap is the fault, and none of the work on the unit applies. Crank for three seconds so the trace has time to settle before you judge it.
Do the same at the cam sensor, because the unit needs both signals before it will fire in sequence. A cam signal that drops out at low speed leaves the unit waiting and the engine cranking. Compare the two traces on one screen if the scope has two channels, and note where the cam edge falls against the crank pattern.
Read the live values for the start authorisation in the engine unit while the key is turned. A unit that reports the authorisation as refused has answered the question, and the spark and fuel tests then only confirm what the value already says. Write the value down before anything is cleared, since a cleared entry takes the evidence away.
Then read the immobiliser side and confirm that the key is accepted there. A key that the carrier accepts and the engine unit refuses is the classic mismatch, and it appears after a swap and after a failed write. Test the second key as well, with the two keys well apart, because a car that reads both at once reports a key present and then declines to start.
The unit is the fault when the feeds hold through the crank, the ground drop is low, both signals are clean, the rail reaches its value and no injector plug shows a pulse while the coils still spark. Those results together leave the driver stages as the repair, and the unit goes on the bench for a stage test under load.
A unit that pulses one cylinder and not the others is behaving as a partly failed unit does, and it goes on the bench for a stage repair with a used part of unknown history kept out of the car. Write every reading on the sheet before the unit leaves the car. Read the entries again after the repair so the change is visible, and cycle the key twice before the road test. Keep the old unit until the car has done a cold start and a hot restart.
Read the authorisation value before you touch the ignition side, because a car that cranks with a clean crank trace and a full rail is usually a decision inside the unit. Measure the feeds with the plug fitted and the grounds on the millivolt range, then scope an injector plug on two cylinders. A unit that sparks and never pulses has given you the answer, and the bench test confirms it.
| Symptom | Likely cause | What is measured |
|---|---|---|
| Cranks at normal speed, never catches | Unit holding injection back | Live start authorisation value with the key turned |
| Coils spark, no injector pulse on any cylinder | Driver stages inside the unit | Scope at two injector plugs during the crank |
| Cranking voltage falls under ten volts | Battery or a feed | Battery under load, ignition feed at the unit |
| Rail stays at zero while the pump runs | Low side pressure or the pump | Gauge at the pump outlet, clamp on the pump feed |
The starter is enabled on this car even when the start authorisation is refused, so the engine turns and never fires. The refusal is visible in the live values of the engine unit.
One stage fails on its own and leaves three cylinders working, which gives a rough idle. All stages shut down when the unit loses its supply reference, which gives a crank with no fire.
A used unit carries the coding of the car it came from and needs the alignment written before it will fire. Save the data from both sides first, since a failed write leaves the pair out of step.
The engine is started from cold, the entries are read again, and the rail pressure is watched through a hot restart. A pulse that disappears when hot means the stage test was not done under load.